  MediTell2 ECU
 

Ventcroft Disabled Persons Response Alarm  has been designed for both easy end user  operation and simple engineer installation and maintenance. The Control unit is micro processor controlled  and is feature rich yet very simple to operate.

Easy to install.
Two Wire Fielded Device operation
3 Status LED's
Battery Back Up option.
Built In Buzzer
Mute / Reset Button
Field Device End-of-Line Monitoring.
Simple to operate
2 Year Warranty.


Ventcroft Meditell 2 ECU

 



 

Key Features   

 

  Simple 2 Wire operation for all field devices

  Battery Back up Option

  Simple Maintenance and Fault Diagnosis.

  On Board Buzzer.

  3 Front Mounted Status LED's

  Front Mounted Mute / Reset Button.

  Full Range of Field Devices Available.

  Engineer Field Test Device Available.


back to top
 

VEN Explanation, Connecting Field Devices

 

VEN, Ventcroft Equivalent Number, allow simple management of the number of filed devices that can be connect to the



 

Description   

 

Ventcroft's Disabled Person Toilet Alarm should be fitted in disabled toilets to enable a distressed person to summon response,  it has been designed for simple installation and easy user operation. The British building regulations The unique  two wire field device operation makes installation fast and simple, in normal operation the filed wiring operates the input for the input devices, when a input device is pressed the filed wiring then become drives the over door indicators and sounders.


back to top
 

Detailed  Features   

 

Simple 2 Wire operation for field devices
   
All field devices and connected in parallel using two core cables.

Call and Attendant Response Alarm available from the same 2 wire field cables.
 
- Call devices, and indicators connect on the same two wires, each devices has in and out terminals

  Built in  Buzzer
  
- Can be Muted By mute button.
   - When pressed during fault condition will bleep once every 10 seconds.
   - When Pressed during Call activation will bleep once every 5 seconds. 


  3 Status LED's
 
   - Green:  Mains Power         - Illuminated        - Mains On
                                                - Flashing 0.5 hZ  - Battery Back Up, Mains Off
                                                -  Blink    (1 / 15s)  - back up battery below 10V with deep discharge protection
                                                 activated.

   - Red:      Call Status            Flashing    0.3Hz       - Call  Pull cord activated
                                               Fast Flashing  1Hz     - PA "Attendant Response Call"

   - Yellow:  Fault                     Constant   -  Field Wiring damaged ie, either shorted or Open Circuit
                                                or damaged button.
                                                Blinking    - Field devices shorted, this mode is only available during initial
                                                power up and after as master reset

Front Mounted Mute / Reset Button
    - During a fault condition the buzzer is muted by pressing the mute button, once muted the buzzer will bleep
      once every 10 seconds .

    - During a Call Activation the buzzer is muted by pressing the mute button, once muted the buzzer will
      bleep once every 5  seconds . When a Call is muted the field devices continue to sound and flash.

    - Once Muted a call may cleared by pressing the mute button for 1 second which will clear  the Control  
      unit to standby mode and stop the field device from sounding and flashing.

    - At any time during standby / quiescent mode if  the reset button is  pressed for 3 seconds the Control Unit
      will perform a master reset equivalent to initial powering up, which will test all LED's and internal buzzer
      and field sounder devices.

    - During Mains Fail and battery backup, the Internal Buzzer will bleep once every two seconds, the mute
      button can be pressed which will allow the mains fail warning bleep to be once every 60 seconds.

    - The mute button, will not mute an "Attendant Response Call"


Battery Back up Option
   - 24 Hours Stand - By with 12V 1.2 Ahr Sealed Lead Acid battery
   - When the mains have failed and battery is discharged to 10V  the deep discharge battery protection is
     enabled which turn off the control unit so protecting the battery and prolonging it life. The power LED will
      flash on every 15 seconds.


Field Device End of Line Monitoring
   - All field device wiring and devices including, Assistance Pull Cords, PA call devices, Over Door Indicators,  
    and Mute / Reset devices are continually monitored for open &  short circuit and jammed buttons.

  Solid State Active Short Circuit Protection
 
 - If a short circuit or over currant is presented across the Zone field connection terminals  the control unit
     automatically Shuts down the power to the devices, and illuminates the fault LED while sounding the fault
    buzzer.  This special feature offers many benefits including self protecting electronics for long life, Less fuses
    to  replace, and simple engineer fault diagnosis during installation and maintenance.

  Deep Discharge Battery Protection.
 
 - During a mains failure, and operating on battery back up, the battery in constantly monitored ensuring that
      it does not fall below 10V which is the lowest a sealed lead  battery should be discharged to. At 10V the
      Control will automatically go to sleep preserving the rechargeable battery. The green power LED will blink
      once every 15 seconds during deep discharge sleep mode.

  Power Up Self Test.
  - On initial power up the control unit will flash each LED in sequence and sound the
    onboard Buzzer, then test field device  wiring for end of line presence , shorts &  open
    circuits and jammed buttons, on passing testing the field device will flash and sound
     twice.


back to top
 

 

Easy Installation & Commissioning.

 

Simple Installation.
 
The Ventcroft Call Response unit CR1 is simple to install, simply fit the field devices and the control unit in the required locations. Then wire with two or great core cable observing the polarity. The filed Device has terminals for both in and out making connections simple and easy. Now wire and through a fused spare to the CR1 control unit.

Commissioning.

Turn on mains Power, the control unit will

 


back to top
 

Simple User Operation

 

Stand By
 
Green  Power LED Illuminated and indicates healthy operation.

 

 


back to top
 

Connections

 

Mains Connections

L
N
E

Operation Connections

Battery + / -         


 

 



 

Simple Connection Diagram

 

 


back to top
 

Detailed Specifications

Disabled Persons Response Alarm

 Power Supply

Mains Input Voltage

230Vac 50Hz
Transformer  Primary Thermal  Fuse 1A 102 DEG C. (Non Replaceable))
Quiescent Standby Current 18mA dc (Buzzer Muted)
Maximum Overall Supply Current 300 mA dc (Max.)
Maximum On-Board Sounder  Current 5 mA
Maximum Filed Zone Output Current 200 mA
     
 User Operation

Buttons

Mute / Reset
     
 LED's Front Mounted 
                       
                              
Mains - Green Constant:   Mains Present
Flashing:   On Battery Back Up
Call    -  Red Constant:
Flashing:
Fault  -  Yellow Constant:
Flashing:
Pulsing with Mans LED:  On battery
     
Internal Buzzer Type Peizo, PCB Mounted
     
 Battery Standy

Current Draw  - Fault Buzzer On.

61mA (0.061A)
Current Draw  - Fault Muted 53mA (0.053A)
Current Draw - 95mA (0.095A)
     
Zone Circuit

Number of Zone Circuits

1
Detection Supply Voltage 12Vdc +/- 10%
Maximum Current Sourcing 15mA (0.015A)
Monitoring Healthy              2mA <> 7.5mA (Nom.)
Fire                   17mA <>  41mA (Nom.)
Short Circuit      >43mA (Nom.)
Open Circuit      <2mA

20 Low Current Types >30uA)
Maximum Input Devices per Zone 4
Maximum Over Door Indicators Per Zone 3
     
 Battery Input Battery Charging Voltage

Monitoring
 
13.6 Vdc

Less than 10Vdc (Deep Discharge Protection)
Reversed
     
Fuses F1:

500mA Anti Surge  20mm Glass

F2: 500mA
Mains Transformer Thermal Fuse. 1A 102 deg. C (non replaceable)
     
Housing

Front Cover

Polycarbonate - Fire Retardant.

Back Box

Polycarbonate - Fire Retardant.
     
Compliance

European

CE
Ingression Protection Rating. IP20
     
Re-Ordering Control Unit VC-
     
Warranty Period 2 Years from of Manufacture
Identification Date of Manufacture Marked On PCB


back to top
 

Part Numbers :  Disabled Persons Toilet Alarm  System

 DESCRIPTION

Part Number

 Trade Price
£ (GBP)

Surface Mount Call response control unit, with three status LED's, internal buzzer, mute / reset button.
230 Vac mains input, and 12V SLA battery back up option, 373g. Quiescent Current 18mA. Max. Zone O/P Current 200mA.
PCB44.1 - A1r