UK  

  VENTCROFT     FIRE and  LIFE SAFETY

 

 
 
    |  products  |  fire   |  detection  |  conventional  |  apollo   | series 60
Apollo Series 60                Apollo logo         
Ventcrofts range of Apollo Fire Detection devices include series 60 and series 65 families.  Both families include optical and ionisation smoke detectors and a comprehensive range of fixed heat and rate of range detection devices with a common base with schotky diode.
Optical &  Ionization smoke detection models
Rate of Rise and Fixed Heat
Detection models
BS EN50130-4:1996
Common Base Design
Quick Fit Bayonet Base
Remote Detector Activated LED     Output
Full Rage of Heat Detectors,
Grades 1,2 & 3 and  Ranges 1 & 2.
Locking Grub Screw
1 Year Warranty


 Apollo Low Profile Smoke Detector

 
 

Description

Description

Heat Detection. The Series 60 heat detectors are resettable and operate by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. During normal conditions the two thermistors register similar temperatures, but, on the development a fire, the temperature recorded by the exposed thermistor will increase rapidly, resulting in imbalance of the thermistors and causing the detector to change to the alarm state. Rate of rise detectors are designed to detect a fire as the temperature increases, but they also have a fixed upper limit at which the detector will go into alarm if the rate of temperature increase has been too slow to trigger the detection earlier. Fixed heat detectors only change to the alarm state at a preset temperature.

IONISATION SMOKE DETECTOR. The sensing part of the detector consists of two chambers – an open, outer chamber and a semi-sealed reference chamber within. Mounted in the reference chamber is a low activity radioactive foil of Americium 241 which enables current to flow between the inner and outer chambers when the detector is powered up. As smoke enters the detector, it causes a reduction of the current flow in the outer chamber and hence an increase in the voltage measured at the junction between the two chambers. The voltage increase is monitored by the electronic circuitry which triggers the detector into the alarm state at a preset threshold. An externally visible LED will light up when the detector changes to alarm state.

OPTICAL SMOKE DETECTOR.  Optical smoke detectors incorporate a pulsing LED located in a labyrinth within the housing of  the detector. The labyrinth is designed to exclude light from any external source. At an angle to the LED is a photo-diode which normally does not register the column of light emitted by the LED. In the event of smoke from a fi re entering the labyrinth the light pulse from the LED will be scattered and hence registered by the photo-diode. If the photo-diode "sees" smoke on the two following pulses, the detector changes to the alarm state when the indicator LED will light up. The detector housing is identical to that of the ionisation smoke detector. It is distinguished from this type by having an indicator LED which is clear in quiescent state but produces red light in alarm. The optical detectors are easy to disassemble and clean without the necessity of returning them to the factory.

 

Part Numbers : Apollo Series 60 Conventional Smoke Detection 

 

 DESCRIPTION

Part Number

 Trade Price
£ (GBP)  Ex VAT.

Apollo Series 60 Optical (Photo-Electric) Smoke Detector 24V, Fire Activated LED.
Requires VDB-60SD/A or VDB-60S/A Base.
Manufacturing Code: 55000-300
VFD-60P/A £ 35.42
Apollo Series 60 Ionization Smoke Detector 24V, Fire Activated LED.
Requires VDB-60SD/A or VDB-60S/A Base.
Manufactures Code: 55000-200
VFD-60I/A £ 35.42
Apollo Optical Series 60 smoke Detector and combined 57 Deg. C. Heat Detection Element, 24V
Requires VDB-60SD/A or VDB-60S/A Base.
Manufactures Code: 55000-380
VFD-60PH57/A £ POA
 

Part Numbers : Apollo Series 60 Conventional Heat Detection

 DESCRIPTION

Part Number

 Trade Price
£ (GBP)

Apollo n bHeat detector Grade 1, with 60 Deg. C. heat element, Fire Activation LED LED's, EN54, BS5839. Re-settable Action, also combines a rate of rise action.
Requires VDB-60SD/A or VDB-60S/A Base.
The VFD-60H60/A offers response time.

Manufacturing Code: 55000-100

VFD-60H60/A

£ 20.87
Apollo Heat detector Grade 2, with 65 Deg. C. heat element, Fire Activation LED LED's, EN54, BS5839. Re-settable Action, also combines a rate of rise action.
Requires VDB-60SD/A or VDB-60S/A Base.

Manufacturing Code: 55000-101

VFD-60H65/A

£ 20.87
Apollo Heat detector with 75 heat element, Grade 3 Fire Activated LED, EN54. BS5839. Re-settable Action,  Also combines a rate of rise action.
Requires VDB-60SD/A or VDB-60S/A Base.

Manufacturing Code: 55000-102

VFD-60H75/A

£ 20.87
 

Part Numbers : Series 60 Apollo Conventional Detector Bases

 DESCRIPTION

Part Number

 Trade Price
£ GBP Ex VAT.

Apollo Series 60 Fire Detector base with Shcottky Diode.
Suitable for series 60 and 65.

Manufacturing Code: 45681-201
Buy On Line      arrowCPC
VDB-60SD/A £ 5.36 green flag
Apollo Fire Detector base, standard
Suitable for series 60 and 65.

Manufacturing Code: 45681-200
VDB-60S/A £ 5.36
 

Part Numbers : Series 60 Apollo Mounting Accessories

 DESCRIPTION

Part Number

 Trade Price
£ GBP Ex VAT.

Apollo Series 60 Back Plate mounting accessory.
Suitable for series 60 and 65.

Manufacturing Code: 45681-233
 
VFA-60BP £ 2.78
Apollo Series 60 Conduit Box mounting accessory.
Suitable for series 60 and 65.

Manufacturing Code: 45681-204
VFA-60CB £ POA
 

Detailed Information

 

 
arrowfire Alarms arrowIntruder Alarms arrowResponse Alarms arrowemergency lighting arrow  
back to top
 
 

arrow.gif © Copyright 1991-2006 Ventcroft Ltd.