Ventcroft Enhanced Fire Performance Cables





Red Enhanced Fire Cable
 

Many schools, collages, public buildings or where the very best protection is required, now demand the 2 hour duration provided by an 'Enhanced' Fire Cable. NoBurn Diamond Enhanced meets this requirement and is approved by LPCB to the 'Enhanced' standard of BS5839-1 2002 26.2e and also the requirements of BS8434 - 2 120 minutes and BSEN50200 Class PH120.

NoBurn Diamond's Firelok design adds simple but effective strength and makes NoBurn Diamond cable the fastest enhanced cable to install and prepare for installation. The outer sheath and foil are adhered so together are removed at the same time, no time consuming multiple sheaths, foils, wraps or mica tapes to remove.

More flexible than most enhanced fire cable, NoBurn Diamond stays where you put it - simple and easy to dress and position in conduit or trunking.

NoBurn cores are manufactured with multiple twists to provide the highest level of data protection , ideal  for long cable runs and analogue addressable fire systems. NoBurn softskin enhanced fire cable provides a cost effective quick to install alternative to MICC cables.

Also suitable for automatic lift doors, air conditioning and computer control  where low smoke, fume and zero halogen cable is required. 

Features

Fastest Enhanced Fire Cable to Prepare for Termination
Easy to Install with Increased Working Flexibility Twisted
Cores to Provide High Level Data Protection
Full Size CPC (Earth Core)
Red & White Outer Sheaths Available
1mm, 1.5mm & 2.5mm
500 Metre and Special Lengths Available
Copper / Co-polymer Foil Screen

Approved and Certified to meet

BS5839 - 1:2002 Clause 26.2e
BS8434 - 2:2002 120 Minutes
BSEN50200:2006 PH120
BS7629-1:1997
BS6387:1994 Clause CWZ-11
BSEN50267-2-1:1999
BSEN50268-2:2000

Also Approved For
BS5266-1:2005

back to top

Accreditations and third Party Certification



LPCB Product Certification


lpcb logo

LPCB Quality Management
ISO9001:2000 Certification

 

back to top

Firelok Design

NoBurn Diamond's unique 'Firelok' design removes overlap vulnerability during fire conditions . Sprinkler systems and water used by fire fighters has the potential to cause a reduction of a fire alarm cable's continuity and therefore the operation of a fire system and safety devises attached.

Added Strength (at Vulnerable Foil Overlap) - Improved Fire Protection

Protects Circuit Integrity - Prevents Water Ingress During Fire Conditions

Minimizes Accidental Installation Damage

Reduced Number of Sheaths - Faster & Lower Installation Cost

 

Manufacturers Recommended Installation Guide Lines
Recommended clip spacing 300mm Horizontal, 400mm Vertical

Minimum recommended installation temp. 0ºc

Installation methods for current rating in accordance with BS7671/EE Wiring Regulations

The tabulated ratings are based upon 30ºc ambient temperature and 70ºc operating temperature.

Minimum Bend Radius = 6 x Diameter

back to top

BS5839, Part 1:2002 Update

A recent amendment to BS5839, (fire detection and fire alarm systems for buildings - Code of practice for system design, installation, commissioning and maintenance) has been issued. The new Standard BS5839 Part 1:2002 details many revisions but in particular the use and standards of Fire Performance Cables.

More Information

back to top

Downloads

The download drop down box allows you to download files for the products on this page. Files include, Instruction Manuals, Sales leaflets, Specifications and Certificates. Adobe Acrobat Reader may be required to read some of the file, a link is included to download the reader if you require it.Get Adobe Reader


 

back to top

Ventcroft Enhanced Fire Performance Cable

         Red

Red 1.5mm Cores & CPC Earth

Reel Cores Code Pallet Min Qty Trade Per 100m

 

 

 

 

1.5mm

100m 2 Cores & CPC VEP-215ERH 60 1 TBA

1.5mm

100m 3 Cores & CPC VEP-315ERH 60 1 TBA

1.5mm

100m 4 Cores & CPC VEP-415ERH 60 1 TBA

1.5mm

200m 2 Cores & CPC VEP-215ERH200MWR 20 1 TBA

1.5mm

200m 4 Cores & CPC VEP-415ERH200MWR 20 1 TBA

1.5mm

500m 2 Cores & CPC VEP-215ERH500MWR 10 1 TBA

1.5mm

500m 4 Cores & CPC VEP-415ERH500MWR 10 1 TBA

Red 2.5mm Cores & CPC Earth Reel Cores Code Pallet Min Qty Trade Per 100m

2.5mm

100m 2 Cores & CPC VEP-225ERH 60 1 TBA

2.5mm

200m 2 Cores & CPC VEP-225ERH200MWR 20 1 TBA

2.5mm

500m 2 Cores & CPC VEP-225ERH200MWR 10 1 TBA

*Cable prices will vary due to changes to copper costs*

back to top

Fire Performance Cable Part Code Break Down

VFP-215ER

VEP - 2 15 E R H  
Product Type   Conductors CSA CPC Type Outer Sheath Colour Core Colours Length
Ventcroft Fire Performance
Cable "NoBurn Diamond"

 

  2 - 2 Core

4 - 4 Core

10 - 1.0mm

15 - 1.5mm

25 - 2.5mm

E - CPC & Screen
 
R - Red

W - White

H- Harmonised Colours

- Old Colours

 

- 100M

50 - 50M

500 - 500M

750 - 750M

(M = Meter)

 

 Revised:15/02/2008

 

 

Intruder Alarms Response Alarms    
back to top
 
 