Now one of the leading brands of fire cable. NoBurn Platinum fire cable is manufactured in the UK using the latest technology, materials and manufacturing equipment. Our materials and production processes are audited by LPCB and BASEC to ensure consistent reliability and quality, with each reel fully traceable by batch number and time and date of manufacture.

NoBurn Platinum is the fastest fire cable to prepare for termination with no troublesome multiple sheaths, foils or wraps to strip, NoBurn Platinum cable has superb working flexibility and stays where you put it, reducing installation time and costs.

Approved by LPCB and BASEC to meet with BS 5839-1:2002+A2:2008 Clause 26.2d Standard, BS EN 50200:2006 + Annex E 30 minutes & BS EN 50200:2006 Class PH120, NoBurn Platinum's core twists will provide the highest level of data protection, ideal for long cable runs and analogue addressable fire systems. Also certified by LPCB and BASEC to BS 7629-1:2008  & BS 6387:1994 Clause 11 CWZ including 3 hour burn test at 950°c.

NoBurn Platinum fire cable is also the most highly certified cable for use with Emergency Lighting Systems, certified to exceed BS 5266-1 2005's EN 50200 PH60 - 1 hour duration, NoBurn Platinum is certified by LPCB and BASEC to withstand to PH120 - providing 2 hours of protection. Also suitable for automatic lift doors, air conditioning and computer control where low smoke, fume and zero halogen cable is required.

 

 Features

Fastest Standard Fire Cable to Prepare for Termination
Easy to Install and Superb Working Flexibility
Twisted Cores to Provide High Level Data Protection
Full Size CPC (Earth Core)
Red, White & Black Outer Sheaths Available
1mm²,1.5mm², 2.5mm² & 4.0mm²
500 Metre and Special Lengths Available
Aluminium / Co-polymer Foil Screen
 Approved and Certified to meet

BS 5839-1:2002 +A2:2008 Clause 26.2d

'Standard' Fire Cable
BS EN 50200:2006 + Annex E 30 Minutes Fire Resistance Standard
BS EN 50200:2006 PH120 Fire Resistance Standard
BS 7629-1:2008 Fire Resistance Standard
BS 6387:1994 Clause 11 CWZ Fire Resistance Standard
BS EN 50267-2-1:1999 Halogen Emission Standard
BS EN 61034-2:2005 Low Smoke Standard
 Also Approved For
Emergency Lighting Standard BS 5266-1:2005
Voice Alarm Systems Standard BS 5839-8:2008
Voice Communication Standard BS 5839-9:2003
   (Risk Assessment May Demand Mechanical Protection)


 

 Accreditations and third Party Certification



 

LPCB Quality Management
ISO9001:2008 Certification

LPCB Product Certification
682a


 



 



 


BASEC Quality Management
ISO9001:2008 Certification

BASEC
BS7629-1:2008 Certificate

BASEC
BS5839-1:2002 Certificate

 

 Manufacturers Recommended Installation Guide Lines


Recommended metal clip spacing 300mm Horizontal, 400mm Vertical

Recommended Cable Tray Fastening - Metal Tie, spacing every 1.5 metres.

Installation Temperatures:
Minimum installation Temperature
0ºc
Maximum installation Temperature 70 C

Operating Temperature Temperature:
Minimum -40 C to Maximum +90 C

The cable should not be flexed or bent when either the cable or operating temperature is below the recommended installation temperatures.

Minimum Bend Radius = 6 x Diameter
Plastic Clips or ties must not be used as the sole means of support for fire cable.

 

back to top

BS5839, Part 1:2002 Update

A recent amendment to BS 5839, (fire detection and fire alarm systems for buildings - Code of practice for system design, installation, commissioning and maintenance) has been issued. The new Standard BS 5839 Part 1:2002 details many revisions but in particular the use and standards of Fire Performance Cables.

More Information

back to top

Downloads

The download drop down box allows you to download files for the products on this page. Files include, Instruction Manuals, Sales leaflets, Specifications and Certificates. Adobe Acrobat Reader may be required to read some of the file, a link is included to download the reader if you require it.Get Adobe Reader


 

back to top

NoBurn Platinum Standard Fire Performance Cable

           Red

Red 1mm Cores & CPC (earth) Reel Cores Code Pallet Min Qty Trade Per 100m

 

1mm 100m 2 Cores & CPC

VFP-210ERH

60 1 TBA
1mm
 
100m 3 Cores & CPC

VFP-310ERH

60 1 TBA
1mm 100m 4 Cores & CPC

VFP-410ERH

60 1 TBA
1mm 500m 2 Cores & CPC

VFP-210ERH500M

10 1 TBA

 

Red 1.5mm Cores & CPC (earth) Reel Cores

Code

Pallet Min Qty Trade Per 100m
1.5mm 100m 2 Cores & CPC

VFP-215ERH

60 1 TBA
1.5mm 100m 3 Cores & CPC

VFP-315ERH

60 1 TBA
1.5mm 100m 4 Cores & CPC

VFP-415ERH

60 1 TBA
1.5mm 200m 2 Cores & CPC

VFP-215ERH200M

20 1 TBA
1.5mm 200m 4 Cores & CPC

VFP-415ERH200M

20 1 TBA
1.5mm 500m 2 Cores & CPC

VFP-215ERH500M

10 1 TBA
1.5mm 500m 4 Cores & CPC

VFP-415ERH500M

10 1 TBA 

Red 2.5mm Cores & CPC (earth) Reel Cores

Code

Pallet Min Qty  Trade Per 100m
2.5mm 100m 2 Cores & CPC

VFP-225ERH

60 1 TBA
2.5mm 100m 3 Cores & CPC

VFP-325ERH

60 1 TBA
2.5mm 100m 4 Cores & CPC

VFP-425ERH

60 1 TBA
2.5mm 200m 2 Cores & CPC

VFP-225ERH200M

20 1 TBA
2.5mm 500m 2 Cores & CPC

VFP-225ERH500M

10 1  TBA

Red 4mm Cores & CPC (earth) Reel

Cores

Code

Pallet Min Qty Trade Per 100m
4mm 100m 2 Cores & CPC

  VFP-S240ERH

60 1 TBA

back to top

NoBurn Platinum Standard Performance Cable

       White

Red 1mm Cores & CPC (earth) Reel Cores Code Pallet Min Qty Trade Per 100m

 

1mm 100m 2 Cores & CPC VFP210EWH 60 1 TBA
1mm 100m 3 Cores & CPC VFP-310EWH 60 1 TBA
1mm 100m 4 Cores & CPC VFP-410EWH 60 1 TBA
1mm 500m 2 Cores & CPC VFP-210EWH500M 10 1 TBA

 

White 1.5mm Cores & CPC
(earth)
Reel Cores Code Pallet Min Qty Trade Per 100m
1.5mm 100m 2 Cores & CPC VFP-215EWH 60 1 TBA
1.5mm 100m 3 Cores & CPC VFP-315EWH 60 1 TBA
1.5mm 100m 4 Cores & CPC VFP-415EWH 60 1 TBA
1.5mm 200m 2 Cores & CPC VFP-215EWH200M 20 1 TBA
1.5mm 200m 4 Cores & CPC VFP-415EWH200M 20 1 TBA
1.5mm 500m 2 Cores & CPC VFP-215EWH500M 10 1 TBA
1.5mm 500m 4 Cores & CPC VFP-415EWH500M 10 1 TBA

White 2.5mm Cores & CPC (earth) Reel Cores Code Pallet Min  Qty  Trade Per 100m
2.5mm 100m 2 Cores & CPC VFP-225EWH 60 1 TBA
2.5mm 100m 3 Cores & CPC VFP-325EWH 60 1 TBA
2.5mm 100m 4 Cores & CPC VFP-425EWH 60 1 TBA
2.5mm 200m 2 Cores & CPC VFP-225EWH200M 20 1 TBA
2.5mm 500m 2 Cores & CPC VFP-225EWH500M 10 1  TBA

White 4mm Cores & CPC (earth) Reel Cores Code Pallet Min Qty Trade Per 100m
4mm 100m 2 Cores & CPC

  VFP-S240EWH

60 1 TBA

back to top

NoBurn Platinum Standard Fire Performance Cable

    Black       Black Reel Cores Code Pallet Min Qty Trade Per 100m

1.5mm 100m 2 Cores & CPC VFP-215EBKH 60 1 TBA
2.5mm 100m 2 Cores & CPC VFP-225EBKH
      
60 1 TBA
1.5mm 100m 4 Cores & CPC VFP-415EBKH 60 1 TBA

*Cable prices will vary due to changes to copper costs*

back to top

Fire Performance Cable Part Code Break Down

VFP-210ER

VFP - 2 10 E R H  
Product Type   Conductors CSA CPC Type Outer Sheath Colour Core Colours Length
Ventcroft Fire Performance
Cable "NoBurn Platinum"

 

  2 - 2 Core

4 - 4 Core

10 - 1.0mm

15 - 1.5mm

25 - 2.5mm

E - CPC & Screen
 
R - Red

W - White

H- Harmonised Colours

- Old Colours

 

- 100M

50 - 50M

500 - 500M

750 - 750M

(M = Metre)

 

EC Declaration of Conformity
 

Full Part Code break down including Specials

Understanding the Standards and Tests

 

 Revised:04/04/2011

 
 
         
back to top
 
 

arrow.gif © Copyright 1991-2011 Ventcroft Ltd.