UK  

  VENTCROFT     FIRE and  LIFE SAFETY

 

 
 

  << :: products ::  sealed lead acid batteries
Back Up Batteries
 
Sealed Lead Acid
12V
 
 
 
 
 
 
1 Year Warranty.

 

 

 

 

Description

The VB/Y range of sealed lead acid batteries are ideally suited for Fire alarm  and Intruder Alarm applications. The VB/Y range has been specially designed for standby by applications and not for cyclic applications.

Key Features

  Fast on terminals
Designed for float charge  stand by applications
Small Body Size
No Maintenance
Valve regulated
5 Year Life

Detailed Features

   

Premium
Model
Nominal
Voltage
Nominal
Capacity Ah
(20 hour rate)
Length
(mm)
Width
(mm)
Height
(mm)
Weight
(kg)

 

VBP-12V1.2/Y
12
1.2
97
48
55
0.6
VBP-12V2.1/Y
12
2.1
178
34
64
0.9
VBP-12V2.8/Y
12
2.8
134
67
64
1.1
VBP-12V3.2/Y
12
3.2
134
67
64
1.2
VBP-12V7/Y
12
7
151
65
98
2.7
VBP-12V12/Y
12
12
151
98
97.5
4.0
VBP-12V17/Y 12 17 181 75 167 6.1

Yuasa's unique construction and sealing technique ensures that no electrolyte leakage should occur from the terminals or case of any NP battery This feature provides for safe and effective operation of NP batteries in any orientation. Yuasa NP batteries are classified as "Non Spillable" and meet all requirements to the International Air Transport Association (l. A. T.A  Dangerous Goods Regulations).

All Yuasa NP batteries utilise an electrolyte suspension system consisting of a glass fibre separator material. This suspension system helps to achieve maximum service life, by fully retaining the electrolyte and preventing its escape from the separator material. No silica gels or other contaminants are used.

NP batteries incorporate a unique Yuasa design that effectively recombines over 99% of the gas generated during normal usage.

During the life of NP batteries, there is no need to check their specific gravity or add water etc. In fact, there are no provisions for such maintenance functions to be carried out.

The combination of sealed construction and Yuasa's electrolyte suspension system permits operation of NP batteries in any orientation (excluding continuous inverted use) without loss of capacity, electrolyte, or service life. The NP batteries made in our factory in Wales also conform to BS EN61056-1 (1993) and IEC 10561 (1991).

Yuasa NP batteries are equipped with a safe, low pressure venting system, which is designed to release excess gas and reseal automatically in the event of the internal gas pressure rising to an unacceptable level- This low pressure venting system, coupled with the significantly high recombination efficiency, make Yuasa NP batteries one of the safest valve regulated lead acid batteries available.

The heavy duty lead calcium alloy grids in NP batteries provide an extra margin of performance and service life in both float and cyclic applications, even in conditions of deep discharge.

Depending upon the average depth of discharge, over 1,000 discharge/ recharge cycles can be expected from NP batteries.

The expected service life of the standard model NP battery when used in standby applications is typically 5 years; however, experience has shown that their service life often exceeds 6 years, if the NP batteries are operated strictly within specification.

At temperatures of between 20 & 25°C, the self discharge rate of NP batteries per month is approximately 3% of their rated capacity. This low self discharge rate permits storage for up to one year without any appreciable deterioration of battery performance.

Yuasa NP batteries can be used over a broad range of ambient temperatures, allowing considerable flexibility in system design and location.

Yuasa NP batteries have excellent charge acceptance and recovery capability, even after very deep discharge.

The U.K. manufacturing plant now has Quality Assurance Standard BS5750 Part 2 EN2900, ISO 9002 together with the M.O.D. Quality Assurance AQAP 4.

Construction



 

Detailed Specifications

Housing     Material    
                      
   
Colour    
   
   
   
Dimensions    
   
   
Operating Voltage    
   
   
Current Consumption    
   
   
Standards British Standard    
European Safety    
   
Warranty    

 

Applications


All Standby Application with Float Charge.
Ideal for Fire Alarm and Intruder Alarm Control Panel Applications.
Cable Television
Communications Equipment
Computers
Control Equipment
Electronic Cash Registers
Electronic Test Equipment
Emergency Lighting Systems
Fire & Security Systems
Geophysical Equipment
Marine Equipment
Medical Equipment
Microprocessor Based Office machines
Solar Powered Systems
  Telecommunication Systems
Vending Machines

 SEALED LEAD ACID BATTERIES
DESCRIPTIONS and PART NUMBERS

Description

Part Number

 
  Standard Batteries
     12V 1.2 Ahr, sealed lead acid battery, fast On terminals. VB-12V1.2/Y
     12V 2.1 Ahr, sealed lead acid battery, fast On terminals. VB-12V2.1/Y
     12V 2.8 Ahr, sealed lead acid battery, fast On terminals. VB-12V2.8/Y
     12V 3.2 Ahr, sealed lead acid battery, fast On terminals. VB-12V3.2/Y
     12V 7.0 Ahr, sealed lead acid battery, fast On terminals. VB-12V7/Y
     12V 12 Ahr, sealed lead acid battery, fast On terminals. VB-12V12/Y
     12V 17 Ahr, sealed lead acid battery, fast On terminals. VB-12V17/Y
   Premium Batteries
      12V 1.2 Ahr, Premium sealed lead acid battery, fast On terminals. VBP-12V1.2/Y
      12V 2.1 Ahr, Premium sealed lead acid battery, fast On terminals. VBP-12V2.1/Y
      12V 2.8 Ahr, Premium sealed lead acid battery, fast On terminals. VBP-12V2.8/Y
      12V 3.2 Ahr, Premium sealed lead acid battery, fast On terminals. VBP-12V3.2/Y
      12V 7.0 Ahr, Premium sealed lead acid battery, fast On terminals. VBP-12V7/Y
      12V 12 Ahr, Premium sealed lead acid battery, fast On terminals. VBP-12V12/Y
      12V 17 Ahr, Premium sealed lead acid battery, fast On terminals. VBP-12V17/Y

 

SPARE BATTERIES
DESCRIPTIONS and PART NUMBERS

Description

Part Number

 
  Alkaline Batteries
  1.5V Alkaline AAA Battery VBA-15AAA/CT
   Lithium Batteries
  3V CR123 Battery VBL-3V123/CT
  3V CR2032 Battery VBL-3V2032/CT

 

 
arrowfire Alarms arrowIntruder Alarms arrowResponse Alarms arrowemergency lighting arrow  
back to top
 
 

arrow.gif © Copyright 1991-2006 Ventcroft Ltd.